ALPS EXCLUSIVE AE-08301-MO-V2 (8.3 kW) - Monoblock air/water heat pump
- Sustainable and powerful at low outdoor temperatures
- Compact monoblock design – easy installation and low maintenance
- Smart control – via control panel or optional app
- Active cooling & heating – comfort in every season
Efficient, quiet and ready for the future
The AE-08301-MO-V2 from ALPS EXCLUSIVE is a powerful all-electric monoblock heat pump with a capacity of 8.3 kW. Designed for homes and small commercial projects where performance, ease of installation and sustainability come together. Thanks to the environmentally friendly refrigerant R290, this heat pump is not only efficient but also future-proof within the energy transition.
Sustainable efficiency with R290
The natural refrigerant R290 (propane) has an extremely low GWP value. This limits CO₂ emissions and ensures excellent performance, even in winter outdoor temperatures. In combination with energy class A+++ (at 35 °C), this delivers maximum efficiency, which is immediately noticeable in lower energy costs. Would you like to know how R290 compares to other refrigerants? Then take a look at our page about R290 heat pumps.
Versatile climate solution
With this heat pump, you can heat underfloor heating or low-temperature radiators, prepare hot tap water up to 60 °C and enjoy active cooling in summer. Thanks to modulating inverter technology, the system automatically adjusts its output to the current heat demand. This means no unnecessary peak consumption, less wear and tear and lasting comfort. Would you like to know how this system works in combination with a buffer tank?
Compact and easy to install
The AE-08301-MO-V2 is constructed entirely as a monoblock. The cooling circuit is located in the outdoor unit, so you do not need to install an indoor unit. This reduces installation time, limits piping and makes the system ideal for renovation projects or locations with limited technical space.
Quiet and suitable for urban environments
With a sound pressure of only 53 dB(A), this system is whisper quiet. This makes it suitable for densely built-up residential areas or projects where noise restrictions apply. Do you have a project where noise is a critical factor? We would be happy to help you find the optimal configuration.
Hewa: your partner from advice to delivery
Hewa has been supplying reliable heating and cooling systems to installers, business customers and DIY enthusiasts for over six years. We offer:
- Technical advice on choosing the right heat pump
- Pre-assembled kits for quick installation
- Fast delivery and up-to-date stock information
- Support with R290 applications and subsidy applications
Ready to make your project more sustainable?
Imagine: one system that heats, cools and provides hot water for your home – without a gas connection. Would you like to know if the AE-08301-MO-V2 is right for your situation? Or are you looking for a solution that you can combine with, for example, a tap water boiler? Contact Hewa today for personal advice and competitive project prices.
| Generals | |
|---|---|
| Item number | 390083 |
| EAN Code | 8721082877060 |
| Price excl. VAT | € 3.387,60 |
| Price incl. VAT | € 4.099,00 |
| Sizes ((LxWxH):) | 46 x 108 x 82 cm |
| Technical Specs | |
| Heating capacity range (kW) | 2.5 - 8.3 kW |
| Heating power input range (kW/h) | 0.64~2.18kW/h |
| COP | 3.52 - 4.69 |
| Cooling capacity range (kW) | 2.4 - 5.8 kW |
| Cooling power input range (kW/h) | 0.64 - 2.18 kW/u |
| EER range | 2.65 - 3.04 |
| ErP level (35°C) | A+++ |
| ErP level (55°C) | A++ |
| Refrigerant | R290 |
| Power supply | 230 VAC / 1 Ph / 50 Hz - 60 Hz |
| Max. power input (kW/h) | 3.1 kW/h |
| Max. current (A) | 14.2 A |
| Minimum fuse or circuit breaker (A) | 20 A |
| Wire diameter (mm²) | 2.5 mm² |
| Pipe connection size | DN 25 / G 1 |
| Max. head (m) | 9 m |
| Noise dB (A) | ≤46 dB |
| Net weight (kg) | 112 kg |
| Dimension (W×D×H) mm | 1083x460x820 mm |
| Operation ambient temperature (°C) | -25 ~ 43 ℃ |
| Operating water temperature heating (°C) | 28 ~ 65 ℃ |
| Operating water temperature cooling (°C) | 15 ~ 70 ℃ |
| Operating water temperature domestic hot water (°C) | 7 ~ 35 ℃ |
| Subject | Action |
|---|---|
| ER01 - Incorrect phase protection Error code | View |
| ER03 - Blockage in the water flow Error code | View |
| ER04 - Anti-freeze protection Error code | View |
| ER05 - High pressure fault Error code | View |
| ER06 - Low pressure fault Error code | View |
| ER10 - Frequency converter module communication fault Error code | View |
| ER12 - Exhaust gas temperature protection too high Error code | View |
| ER14 - Water tank temperature sensor fault Error code | View |
| ER15 - Inlet water temperature sensor fault Error code | View |
| ER16 - Evaporator coil temperature sensor fault Error code | View |
| ER18 - Exhaust temperature sensor fault Error code | View |
| ER21 - Ambient temperature sensor fault Error code | View |
| ER23 - Cooling outlet water temperature ultra-cold protection Error code | View |
| ER26 - Radiator overheat fault Error code | View |
| ER27 - Outlet water temperature sensor fault Error code | View |
| ER29 - Return gas temperature sensor fault Error code | View |
| ER32 - Heating outlet water temperature high protection Error code | View |
| ER33 - Coil temperature is too high Error code | View |
| ER34 - Frequency converter module temperature too high Error code | View |
| ER42 - Cooling pipe temperature sensor fault Error code | View |
| ER62 - Economizer inlet temperature sensor fault Error code | View |
| ER63 - Economizer outlet temperature sensor fault Error code | View |
| ER64 - DC fan 1 fault Error code | View |
| ER66 - DC fan 2 fault Error code | View |
| ER67 - Low pressure switch fault Error code | View |
| ER68 - High pressure switch fault Error code | View |
| ER69 - Low pressure protection Error code | View |
| ER70 - High pressure protection Error code | View |