Filters

Fan blade

A fan blade for SPRSUN CGK-V2 LINE heat pumps is used in the outdoor unit and works together with the fan motor to provide correct airflow across the heat exchanger.

This category is intended for installers, service technicians and business customers looking for a suitable fan blade for maintenance, diagnostics or replacement in SPRSUN heat pump systems.

No results.

Selecting a fan blade for SPRSUN CGK-V2 LINE

A fan blade is the mechanical component that creates airflow inside the outdoor unit of the heat pump. In SPRSUN CGK-V2 LINE heat pumps, the fan blade works together with the fan motor to move sufficient air across the heat exchanger.

When replacing the part, it is important that the fan blade technically matches the original component. Pay attention to diameter, blade shape, rotation direction, hub mounting, balance, material version and compatibility with the installed fan motor.

Important when selecting a fan blade

  • Check whether the fan blade is suitable for the SPRSUN CGK-V2 LINE application.
  • Compare diameter, blade shape, hub size and mounting method with the original part.
  • Pay attention to rotation direction, balance and combination with the correct fan motor.
  • In case of damage, also check the housing, motor shaft, bearings and mounting points.
  • Have installation and replacement carried out by an installer or service technician with heat pump expertise.

Airflow, balance and noise level

The fan blade directly affects airflow, noise level and heat exchanger operation. A damaged, dirty or incorrectly installed fan blade can cause vibration and reduce heat pump performance.

During servicing, it is therefore important not only to visually inspect the fan blade, but also to check for imbalance, cracks, deformation, contact with the housing and abnormal noise during operation. Correct installation prevents additional load on the fan motor.

Frequently asked questions

What is a fan blade used for?

A fan blade moves air through the outdoor unit of the heat pump. This allows air to flow across the heat exchanger, which is important for heat absorption, heat release and stable system operation.

Does every fan blade fit a SPRSUN CGK-V2 LINE heat pump?

No, fan blades differ in diameter, blade shape, hub size, mounting method, rotation direction and balance. Always check whether the component matches the original version.

When should a fan blade be replaced?

Replacement may be required in case of breakage, cracks, deformation, imbalance, contact with the housing, damage caused by ice formation or when the part causes abnormal noise or vibration.

Should the fan motor also be checked?

Yes, when the fan blade is damaged, the fan motor, motor shaft, mounting and bearings should also be checked. Imbalance can cause additional load on the motor.

What should I check before ordering?

Check the correct SPRSUN system, diameter, hub mounting, blade shape, rotation direction and combination with the correct fan motor. Always compare the component with the original fan blade.

Stay up to date with the latest news