ALPS EXCLUSIVE AE-18203-MO-V2 - Monoblock air/water heat pump (18.2 kW)
- 18.2 kW heating capacity for large homes and commercial buildings
- ISDE subsidy of €3700 (reference code KA29830)
- Can be used as an all-electric or hybrid system
- Max. supply temperature 75 °C – suitable for existing radiators
Maximum capacity, quiet operation and suitable for all seasons
The ALPS EXCLUSIVE AE-18203-MO-V2 is a robust all-electric monoblock heat pump with a heating capacity of 18.2 kW. This three-phase top model is designed for larger homes, utility buildings and commercial applications where high performance and reliability are required. Thanks to the natural refrigerant R290 (propane), this heat pump combines impressive capacity with minimal environmental impact.
With a maximum flow temperature of 75 °C, the AE-18203-MO-V2 is perfect for projects with existing radiators or high domestic hot water demand. And despite its power, the noise level remains remarkably low, making this heat pump suitable for use in noise-sensitive environments.
High efficiency and sustainable operation
The use of R290 makes this system not only environmentally friendly, but also particularly efficient at low outdoor temperatures. In combination with inverter technology, the output is continuously adjusted to the current heat demand. This prevents unnecessary peak consumption, reduces energy costs and extends the service life. Would you like to know why more and more installers are choosing R290? Visit our R290 heat pumps page.
All-in-one solution for heating, cooling and domestic hot water
The AE-18203-MO-V2 provides heating for underfloor heating, low-temperature radiators and existing high-temperature radiators. It also prepares hot tap water up to 75 °C and the system can function as air conditioning in summer. Would you like to know how to optimally combine this unit with a buffer tank or boilers? We will be happy to advise you on the best configuration.
All-electric and hybrid use
This model is suitable for both fully electric installations and hybrid systems where an existing boiler is retained. Ideal for renovation projects where the transition from gas is being phased in.
Easy installation thanks to monoblock construction
Because the entire cooling circuit is integrated into the outdoor unit, no indoor unit is required and no F-gas certificate is needed for installation. This saves time, reduces piping and makes the system particularly attractive for projects with tight deadlines.
Low noise for its class
With a sound pressure of less than 57 dB(A), the AE-18203-MO-V2 is one of the quietest in its power class. This makes it suitable for installation in residential areas, care facilities and other locations where noise is crucial.
Applications of 18.2 kW capacity
- Large detached houses with higher heat demand and three-phase connection
- Utility buildings such as offices, shops or practice rooms
- Renovation projects with hybrid use
- Buildings with existing radiators thanks to 75 °C supply temperature
- Projects where noise reduction and high temperature are required
Hewa – more than just delivery
Hewa has been supplying high-quality heating and cooling systems for over six years. We offer:
- Technical support before and during the project
- Pre-assembled sets and hydraulic diagrams
- Delivery from stock or by appointment
- Advice on hybrid configurations and subsidy applications
Ready to make your project more sustainable?
Imagine: one unit that easily heats, cools and supplies hot water to your building – all year round. Would you like to know if the AE-18203-MO-V2 is suitable for your situation? Or are you looking for a powerful, quiet and future-proof solution?
Contact Hewa today for personal advice, technical support and competitive project prices.
| Generals | |
|---|---|
| Item number | 390182 |
| EAN Code | 8721225900068 |
| Price excl. VAT | € 4.792,56 |
| Price incl. VAT | € 5.799,00 |
| Sizes ((LxWxH):) | 108 x 48 x 137 cm |
| Specification list | |
| Heating capacity range (kW) | 7.2 - 18.2 kW |
| Heating power input range (kW/h) | 1.38 - 4.65 kW/h |
| COP | 3.91 - 5.22 |
| Cooling capacity range (kW) | 5.6 - 14.1 kW |
| Cooling power input range (kW/h) | 1.8 - 5.38 kW/h |
| EER range | 2.62 - 3.11 |
| ErP level (35°C) | A+++ |
| ErP level (55°C) | A++ |
| Refrigerant | R290 |
| Power supply | 380 VAC / 3 Ph / 50 Hz - 60 Hz |
| Max. power input (kW/h) | 7.1 kW/h |
| Max. current (A) | 13.5 A |
| Minimum fuse or circuit breaker (A) | 20 A |
| Wire diameter (mm²) | 4 mm² |
| Pipe connection size | DN 25 / G 1" F |
| Max. head (m) | 12 m |
| Noise dB (A) | ≤53 dB |
| Net weight (kg) | 165 kg |
| Dimension (W×D×H) mm | 1080x480x1372 mm |
| Operation ambient temperature (°C) | -25 ~ 43 ℃ |
| Operating water temperature heating (°C) | 15 ~ 70 ℃ |
| Operating water temperature cooling (°C) | 7 ~ 35 ℃ |
| Operating water temperature domestic hot water (°C) | 28 ~ 65 ℃ |
| Subject | Action |
|---|---|
| ER01 - Incorrect phase protection Error code | View |
| ER03 - Blockage in the water flow Error code | View |
| ER04 - Anti-freeze protection Error code | View |
| ER05 - High pressure fault Error code | View |
| ER06 - Low pressure fault Error code | View |
| ER10 - Frequency converter module communication fault Error code | View |
| ER12 - Exhaust gas temperature protection too high Error code | View |
| ER14 - Water tank temperature sensor fault Error code | View |
| ER15 - Inlet water temperature sensor fault Error code | View |
| ER16 - Evaporator coil temperature sensor fault Error code | View |
| ER18 - Exhaust temperature sensor fault Error code | View |
| ER21 - Ambient temperature sensor fault Error code | View |
| ER23 - Cooling outlet water temperature ultra-cold protection Error code | View |
| ER26 - Radiator overheat fault Error code | View |
| ER27 - Outlet water temperature sensor fault Error code | View |
| ER29 - Return gas temperature sensor fault Error code | View |
| ER32 - Heating outlet water temperature high protection Error code | View |
| ER33 - Coil temperature is too high Error code | View |
| ER34 - Frequency converter module temperature too high Error code | View |
| ER42 - Cooling pipe temperature sensor fault Error code | View |
| ER62 - Economizer inlet temperature sensor fault Error code | View |
| ER63 - Economizer outlet temperature sensor fault Error code | View |
| ER64 - DC fan 1 fault Error code | View |
| ER66 - DC fan 2 fault Error code | View |
| ER67 - Low pressure switch fault Error code | View |
| ER68 - High pressure switch fault Error code | View |
| ER69 - Low pressure protection Error code | View |
| ER70 - High pressure protection Error code | View |