ALPS EXCLUSIVE AE-14803-MO-V2 - Monoblock air/water heat pump (14.8 kW)
- 14.8 kW heating capacity for residential and small commercial use
- R290 refrigerant with extremely low GWP
- Energy class A+++ (35 °C) for high efficiency
- Heating, cooling and domestic hot water in one system
High capacity, high efficiency and whisper quiet – for residential and small commercial use
The ALPS EXCLUSIVE AE-14803-MO-V2 is a powerful all-electric monoblock heat pump with a heating capacity of 14.8 kW. Designed for homes and small commercial buildings that require reliable, energy-efficient heating and active cooling. By using outside air as a renewable energy source, this system is a sustainable alternative to gas and oil systems – ideal for those who want to invest in future-proof comfort.
Sustainable and powerful with R290
This heat pump uses the natural refrigerant R290 (propane), which has an extremely low GWP value. This means minimal environmental impact and excellent thermodynamic performance, even at low outdoor temperatures. R290 does not damage the ozone layer and is very suitable for the British climate with its changing seasons. Would you like to know why more and more installers are choosing R290? Read more on our R290 heat pumps page.
Complete climate solution
The AE-14803-MO-V2 provides stable heat for underfloor heating, low-temperature radiators and hot water, but can also actively cool in summer. Thanks to modulating inverter technology, the heat pump continuously adjusts its output to the current heat demand. This prevents peak consumption, reduces energy costs and extends the service life of the system.
User-friendly and smartly controlled
The system is equipped with a clear control system that allows you to easily set the temperature and monitor energy consumption. Depending on the configuration, operation via an app is possible, allowing you to manage the heat pump remotely. This gives you more control and insight – and encourages more conscious energy use. Would you like to know how this heat pump can be combined with a buffer tank or indirect water heaters? We would be happy to advise you.
Compact monoblock construction
Because the cooling circuit is fully integrated into the outdoor unit, no indoor unit is required. This saves space, reduces piping and makes installation quicker and easier – both in new builds and renovation projects. The robust outdoor unit is weatherproof and requires little maintenance, ensuring that this system continues to perform reliably in the long term.
Suitable for a wide range of applications
With a capacity of 14.8 kW, the AE-14803-MO-V2 is ideal for:
- Homes with higher heat demand and good insulation
- Small commercial buildings, such as offices or practice rooms
- Renovation projects with limited installation space
- Projects within the energy transition where gas-free living is central
Hewa – your partner in heating and cooling
With over six years of experience, Hewa supplies high-quality heating and cooling systems to installers, business customers and DIY enthusiasts. You benefit from:
- Technical advice on sizing, subsidies and system selection
- Customised configurations with buffer tank or boiler
- Fast delivery from stock
- Support with installation and commissioning
Ready for gas-free comfort?
Imagine: one system that heats, cools and supplies hot water to your home or business – without a gas connection. Would you like to know if the AE-14803-MO-V2 is the right choice for your situation? Or are you looking for a quiet, powerful and sustainable solution?
Contact Hewa today for personal advice, price information and a tailor-made quote.
| Generals | |
|---|---|
| Item number | 390148 |
| EAN Code | 8721082877084 |
| Price excl. VAT | € 4.379,34 |
| Price incl. VAT | € 5.299,00 |
| Sizes ((LxWxH):) | 48 x 108 x 106 cm |
| Specification list | |
| Heating capacity range (kW) | 5.9 - 14.8 kW |
| Heating power input range (kW/h) | 1.13 - 3.83 kW/h |
| COP | 3.86 - 5.22 |
| Cooling capacity range (kW) | 4.3 - 10.8 kW |
| Cooling power input range (kW/h) | 1.39 - 3.99 kW/h |
| EER range | 2.71 - 3.10 |
| ErP level (35°C) | A+++ |
| ErP level (55°C) | A++ |
| Refrigerant | R290 |
| Power supply | 380 VAC / 3 Ph / 50 Hz - 60 Hz |
| Max. power input (kW/h) | 5.2 kW/h |
| Max. current (A) | 9.8 A |
| Minimum fuse or circuit breaker (A) | 16 A |
| Wire diameter (mm²) | 2.5mm² |
| Pipe connection size | DN 25 / G 1" F |
| Max. head (m) | 9 m |
| Noise dB (A) | ≤52 dB |
| Net weight (kg) | 148 kg |
| Dimension (W×D×H) mm | 1083x480x1060 mm |
| Operation ambient temperature (°C) | -25 ~ 43 ℃ |
| Operating water temperature heating (°C) | 28 ~ 65 ℃ |
| Operating water temperature cooling (°C) | 15 ~ 70 ℃ |
| Operating water temperature domestic hot water (°C) | 7 ~ 35 ℃ |
| Subject | Action |
|---|---|
| ER01 - Incorrect phase protection Error code | View |
| ER03 - Blockage in the water flow Error code | View |
| ER04 - Anti-freeze protection Error code | View |
| ER05 - High pressure fault Error code | View |
| ER06 - Low pressure fault Error code | View |
| ER10 - Frequency converter module communication fault Error code | View |
| ER12 - Exhaust gas temperature protection too high Error code | View |
| ER14 - Water tank temperature sensor fault Error code | View |
| ER15 - Inlet water temperature sensor fault Error code | View |
| ER16 - Evaporator coil temperature sensor fault Error code | View |
| ER18 - Exhaust temperature sensor fault Error code | View |
| ER21 - Ambient temperature sensor fault Error code | View |
| ER23 - Cooling outlet water temperature ultra-cold protection Error code | View |
| ER26 - Radiator overheat fault Error code | View |
| ER27 - Outlet water temperature sensor fault Error code | View |
| ER29 - Return gas temperature sensor fault Error code | View |
| ER32 - Heating outlet water temperature high protection Error code | View |
| ER33 - Coil temperature is too high Error code | View |
| ER34 - Frequency converter module temperature too high Error code | View |
| ER42 - Cooling pipe temperature sensor fault Error code | View |
| ER62 - Economizer inlet temperature sensor fault Error code | View |
| ER63 - Economizer outlet temperature sensor fault Error code | View |
| ER64 - DC fan 1 fault Error code | View |
| ER66 - DC fan 2 fault Error code | View |
| ER67 - Low pressure switch fault Error code | View |
| ER68 - High pressure switch fault Error code | View |
| ER69 - Low pressure protection Error code | View |
| ER70 - High pressure protection Error code | View |