ALPS EXCLUSIVE AE-11403-MO-V2 - Monoblock air/water heat pump (8.3 kW)
- 11.4 kW heating capacity for residential and small commercial use
- R290 refrigerant with extremely low GWP
- Energy class A+++ (35 °C) for maximum efficiency
- Heating, cooling and domestic hot water in one system
Powerful, quiet and easy to install – ideal for residential and small commercial use
The ALPS EXCLUSIVE AE-11403-MO-V2 is a modern all-electric monoblock heat pump with a heating capacity of 11.4 kW. Designed for homes and commercial buildings up to approx. 200 m² (with good insulation), this model combines power, efficiency and compactness. Perfect for situations where you need a little extra capacity without compromising on noise level or ease of installation.
High efficiency with R290
The natural refrigerant R290 (propane) has an extremely low GWP value and delivers excellent performance, even at low outdoor temperatures. In combination with energy class A+++ (at 35 °C), this ensures high efficiency and low energy costs. Want to know why R290 is the sustainable choice of the future? Read more on our R290 heat pumps page.
All-in-one climate solution
With the AE-11403-MO-V2, you can heat, cool and prepare hot tap water up to 60 °C. Thanks to modulating inverter technology, the heat pump continuously adjusts its output to the current heat demand. This prevents peak consumption, reduces wear and tear and ensures a stable indoor climate. Would you like to combine this system with a buffer tank or domestic hot water boiler? That's no problem.
Easy installation thanks to monoblock construction
The entire cooling circuit is located in the outdoor unit, eliminating the need for an indoor unit. This saves space, reduces piping and shortens installation time. For installers, this means less complexity, fewer steps and less chance of installation errors.
Quiet and suitable for noise-sensitive locations
With a sound pressure of only 53 dB(A), the AE-11403-MO-V2 is ideal for urban environments, residential areas and commercial projects with noise restrictions. This allows you to combine high power with whisper-quiet operation.
Suitable for a wide range of applications
This heat pump is perfect for:
- New construction projects with low-temperature heating
- Renovations of well-insulated homes
- Small-scale utility buildings such as offices and practice rooms
- Projects within the energy transition where gas-free living is central
Hewa: your partner in heating and cooling
With over six years of experience, Hewa provides reliable solutions for heating, cooling and hot water supply. You benefit from:
- Technical advice on sizing, subsidies and project selection
- Customised configurations with buffer tank or boiler
- Fast delivery from stock
- Support with installation and commissioning
Ready to make your project more sustainable?
Imagine: one system that heats, cools and supplies hot water to your home or business – without a gas connection. Would you like to know if the AE-11403-MO-V2 is suitable for your situation? Or are you looking for a powerful solution that is also whisper quiet?
Contact Hewa today for technical advice, pricing information and a customised quote.
| Generals | |
|---|---|
| Item number | 390114 |
| EAN Code | 8721082877077 |
| Price excl. VAT | € 3.966,12 |
| Price incl. VAT | € 4.799,00 |
| Sizes ((LxWxH):) | 46 x 108 x 96 cm |
| Specification list | |
| Heating capacity range (kW) | 4.5 - 11.4 kW |
| Heating power input range (kW/h) | 0.85 - 2.95 kW/h |
| COP | 3.86 - 5.29 |
| Cooling capacity range (kW) | 2.4 - 5.8 kW |
| Cooling power input range (kW/h) | 1.10 - 2.87 kW |
| EER range | 2.67 - 3.06 |
| ErP level (35°C) | A+++ |
| ErP level (55°C) | A++ |
| Refrigerant | R290 |
| Power supply | 230 VAC / 1 Ph / 50 Hz - 60 Hz |
| Max. power input (kW/h) | 4.1 kW/h |
| Max. current (A) | 18.8 A |
| Minimum fuse or circuit breaker (A) | 25 A |
| Wire diameter (mm²) | 2.5 mm² |
| Pipe connection size | DN 25 / G 1" F |
| Max. head (m) | 9 m |
| Noise dB (A) | ≤50 dB |
| Net weight (kg) | 120 kg |
| Dimension (W×D×H) mm | 1083x460x960 mm |
| Operation ambient temperature (°C) | -25 ~ 43 ℃ |
| Operating water temperature heating (°C) | 20 ~ 75 ℃ |
| Operating water temperature cooling (°C) | 7 ~ 35 ℃ |
| Operating water temperature domestic hot water (°C) | 20 ~ 65 ℃ |
| Subject | Action |
|---|---|
| ER01 - Incorrect phase protection Error code | View |
| ER03 - Blockage in the water flow Error code | View |
| ER04 - Anti-freeze protection Error code | View |
| ER05 - High pressure fault Error code | View |
| ER06 - Low pressure fault Error code | View |
| ER10 - Frequency converter module communication fault Error code | View |
| ER12 - Exhaust gas temperature protection too high Error code | View |
| ER14 - Water tank temperature sensor fault Error code | View |
| ER15 - Inlet water temperature sensor fault Error code | View |
| ER16 - Evaporator coil temperature sensor fault Error code | View |
| ER18 - Exhaust temperature sensor fault Error code | View |
| ER21 - Ambient temperature sensor fault Error code | View |
| ER23 - Cooling outlet water temperature ultra-cold protection Error code | View |
| ER26 - Radiator overheat fault Error code | View |
| ER27 - Outlet water temperature sensor fault Error code | View |
| ER29 - Return gas temperature sensor fault Error code | View |
| ER32 - Heating outlet water temperature high protection Error code | View |
| ER33 - Coil temperature is too high Error code | View |
| ER34 - Frequency converter module temperature too high Error code | View |
| ER42 - Cooling pipe temperature sensor fault Error code | View |
| ER62 - Economizer inlet temperature sensor fault Error code | View |
| ER63 - Economizer outlet temperature sensor fault Error code | View |
| ER64 - DC fan 1 fault Error code | View |
| ER66 - DC fan 2 fault Error code | View |
| ER67 - Low pressure switch fault Error code | View |
| ER68 - High pressure switch fault Error code | View |
| ER69 - Low pressure protection Error code | View |
| ER70 - High pressure protection Error code | View |