ALPS EXCLUSIVE AE-06001-MO-V2 - All-Electric Monoblock Air/Water Heat Pump (6 kW)
- Compact 6 kW monoblock heat pump with natural refrigerant R290
- Up to 75 °C flow temperature – ideal for radiators and underfloor heating
- Ultra-quiet and space-saving design for residential projects
- Complete refrigeration circuit in outdoor unit – no F-gas certification required
- Modulating inverter technology for maximum efficiency
- Compatible with hybrid systems and gas boilers
- Full technical support and stock via Hewa
Compact, efficient and built for the future
The ALPS EXCLUSIVE AE-06001-MO-V2 is a modern all-electric air-to-water monoblock heat pump delivering 6 kW of thermal output. It provides heating, cooling and domestic hot water production for new builds as well as retrofit projects. Using the natural refrigerant R290 (propane), it operates with a very low GWP value and excellent seasonal efficiency, fully aligned with future EU environmental standards.
With a flow temperature of up to 75 °C, the unit is suitable for both underfloor and radiator systems. This makes it a flexible choice for homes and light commercial applications where comfort and energy savings must go hand in hand.
Installer-friendly design
The AE-06001-MO-V2 is engineered for ease of installation. As a true monoblock system, the entire refrigeration circuit is sealed within the outdoor unit, eliminating the need for F-gas certification or refrigerant handling. This significantly reduces installation time and complexity. All hydraulic connections are easily accessible and clearly labelled.
- Plug-and-play installation – only water connections required
- Compact size for tight spaces and urban locations
- Exceptionally low noise operation
- Integrated frost protection and weather-based control
- Comprehensive support and documentation via Hewa
Reliable technology and proven performance
The unit features a DC inverter compressor that continuously modulates output to match the actual heat demand. This reduces start-stop cycles, increases efficiency and extends system life. An electronic expansion valve precisely controls the refrigerant flow for stable operation even at low temperatures.
- High seasonal efficiency thanks to inverter modulation
- Durable stainless-steel plate heat exchanger
- Integrated frost and overheat protection
- Low vibration and quiet fan design
The system’s components are vibration-isolated for silent operation and long-term durability. Service access is straightforward, keeping maintenance simple and cost-effective.
Ready for hybrid systems
The AE-06001-MO-V2 can easily be integrated into a hybrid heating setup. When combined with the hybrid box from Hewa, it can automatically switch between the heat pump and an existing boiler based on temperature or demand. This makes it the perfect solution for gradual transition towards all-electric heating.
Practical applications
- New builds with high energy standards
- Renovation projects with existing radiator systems
- Hybrid systems combining pump and boiler
- Projects requiring low noise emissions
Hewa – your system partner
Hewa supports installers with technical design, configuration and commissioning assistance. We supply compatible buffer tanks, indirect water heaters and installation materials that match the ALPS EXCLUSIVE range, ensuring a fully integrated system from supply to start-up.
Why choose ALPS EXCLUSIVE?
The ALPS EXCLUSIVE brand represents European engineering quality and advanced heat pump technology. The AE series is built for performance, efficiency and comfort – a smart investment for installers and homeowners alike.
Contact & Ordering
Interested in integrating the AE-06001-MO-V2 into your project? Contact Hewa for technical information, availability or a custom quotation. Our team will gladly advise you on the optimal setup for your application.
| Generals | |
|---|---|
| Item number | 390060 |
| EAN Code | 8721225900051 |
| Price excl. VAT | € 3.057,02 |
| Price incl. VAT | € 3.698,99 |
| Sizes ((LxWxH):) | 44 x 108 x 76 cm |
| Technical Specs | |
| Heating capacity range (kW) | 2.5 - 6 kW |
| Heating power input range (kW/h) | 0.48~1.44kW/u |
| COP | 4.16 - 5.21 |
| Cooling capacity range (kW) | 2.6 - 5.3 kW |
| Cooling power input range (kW/h) | 0.53 - 1.37 kW |
| EER range | 3.06 - 3.20 |
| ErP level (35°C) | A+++ |
| ErP level (55°C) | A++ |
| Refrigerant | R290 |
| Power supply | 230 VAC / 1 Ph / 50 Hz - 60 Hz |
| Max. power input (kW/h) | 2.5 kW/h |
| Max. current (A) | 11.5 A |
| Minimum fuse or circuit breaker (A) | 16 A |
| Wire diameter (mm²) | 2.5 mm² |
| Pipe connection size | DN 25 / G 1 |
| Max. head (m) | 9 m |
| Noise dB (A) | ≤46 dB |
| Net weight (kg) | 95 kg |
| Dimension (W×D×H) mm | 1083x440x761 mm |
| Operation ambient temperature (°C) | -25 ~ 43 ℃ |
| Operating water temperature heating (°C) | 28 ~ 65 ℃ |
| Operating water temperature cooling (°C) | 15 ~ 70 ℃ |
| Operating water temperature domestic hot water (°C) | 7 ~ 35 ℃ |
| Subject | Action |
|---|---|
| ER01 - Incorrect phase protection Error code | View |
| ER03 - Blockage in the water flow Error code | View |
| ER04 - Anti-freeze protection Error code | View |
| ER05 - High pressure fault Error code | View |
| ER06 - Low pressure fault Error code | View |
| ER10 - Frequency converter module communication fault Error code | View |
| ER12 - Exhaust gas temperature protection too high Error code | View |
| ER14 - Water tank temperature sensor fault Error code | View |
| ER15 - Inlet water temperature sensor fault Error code | View |
| ER16 - Evaporator coil temperature sensor fault Error code | View |
| ER18 - Exhaust temperature sensor fault Error code | View |
| ER21 - Ambient temperature sensor fault Error code | View |
| ER23 - Cooling outlet water temperature ultra-cold protection Error code | View |
| ER26 - Radiator overheat fault Error code | View |
| ER27 - Outlet water temperature sensor fault Error code | View |
| ER29 - Return gas temperature sensor fault Error code | View |
| ER32 - Heating outlet water temperature high protection Error code | View |
| ER33 - Coil temperature is too high Error code | View |
| ER34 - Frequency converter module temperature too high Error code | View |
| ER42 - Cooling pipe temperature sensor fault Error code | View |
| ER62 - Economizer inlet temperature sensor fault Error code | View |
| ER63 - Economizer outlet temperature sensor fault Error code | View |
| ER64 - DC fan 1 fault Error code | View |
| ER66 - DC fan 2 fault Error code | View |
| ER67 - Low pressure switch fault Error code | View |
| ER68 - High pressure switch fault Error code | View |
| ER69 - Low pressure protection Error code | View |
| ER70 - High pressure protection Error code | View |