- 20 kW heating output for medium to larger buildings
- Manual cleaning for minimal wear and lower maintenance costs
- High efficiency through advanced combustion technology
- 4.3-inch touchscreen for easy operation and settings
- Optional WiFi module for remote control
- Compact design, easy to install in various spaces
- Suitable for radiators, underfloor heating and domestic hot water production
Efficient heating for larger buildings and higher heat demand
The Kepo MC 20 pellet boiler is a durable heating solution for projects requiring more power while maintaining reliability and efficiency. With a thermal output of 20 kW, this model is ideal for larger homes, commercial spaces, care facilities or other buildings with a higher heating requirement. Thanks to manual cleaning and a solid design, the MC 20 is built for low maintenance and long-term performance.
Sustainable heating with wood pellets
The MC 20 uses wood pellets, a renewable and CO₂-neutral fuel that burns cleaner than fossil fuels. The generated heat is transferred via a water circuit to radiators, underfloor heating systems or boilers, making the unit suitable for both space heating and domestic hot water production.
Reliable performance with straightforward maintenance
Unlike the automatic AC series, the MC 20 requires manual cleaning. This design reduces the number of moving parts, minimising wear and lowering the risk of malfunctions. With a few simple steps, the boiler remains in peak condition even under heavy use.
User-friendly operation and flexible control
Equipped with a modern 4.3-inch touchscreen, users can easily set temperatures, weekly schedules and operating modes. An optional WiFi module enables remote operation, ensuring the heating program can always be adjusted to daily routines and demand.
High efficiency, reduced fuel costs
With advanced combustion technology, the MC 20 automatically adjusts air supply and pellet feed to match current heat demand. This ensures consistently high efficiency, lower pellet consumption and stable heat output.
Flexible installation and system integration
Its compact design allows easy installation in plant rooms, storage areas or garages. When paired with a buffer tank, heat storage can be optimised for peak demand. The MC 20 can also be integrated into hybrid heating systems for added flexibility.
Full support from Hewa
Hewa provides technical documentation and a reliable supply programme for installers and end-users alike. Discover our full range of pellet boilers or contact us directly for tailored information.
Interested in finding out if the Kepo MC 20 pellet boiler is right for your project? Get in touch with Hewa today for expert advice, technical details or a customised delivery offer.
| Generals | |
|---|---|
| Item number | 020202 |
| EAN Code | 8721082877756 |
| Price excl. VAT | € 3.098,10 |
| Price incl. VAT | € 2.999,00 |
| Sizes ((LxWxH):) | 83 x 67 x 128 cm |
| Specification list | |
| Weight (kg) | 248 kg |
| Dimension (W×D×H) mm | 670x830x1280 mm |
| Flue pipe diameter (Ø) | 80 mm |
| Pellet tank capacity (kg) | 62 kg |
| Power consumption at start on pellet (W) | 390 W |
| Power consumption in operation (W) | 110 W |
| Nominal voltage (VAC) | 220 - 240 VAC |
| Nominal frequency (Hz) | 50 Hz |
| Water pipe connection size | G 1" M |
| Safety valve pipe connection | G 1/2" F |
| Pump flow rate (L/h) | 1300 L/h |
| Boiler water volume (L) | 53 L |
| Boiler power (kW) | min 5.79 – max 18.50 kW |
| Pellet consumption (kg/h) | min 1.37 – max 4.56 kg/h |
| Water temperature (°C) | min 60 – max 80 °C |
| Min. boiler water pressure (bar) | 0.6 bar |
| Max. boiler water pressure (bar) | 2.5 bar |
| Preferred pellet class | C1 - A1 |
| Boiler class | 5 |
| Energy efficiency | A+ |
| Suitable surface area (m²) | 100 - 160 m² |
| Fuel | Wood pellets |
| Subject | Action |
|---|---|
| How to clean a Kepo pellet boiler faq | View |
| How to replace the igniter of a Kepo pellet boiler faq | View |
| ER01 - Safety thermostat HV1 intervention Error code | View |
| ER02 - Safety pressure switch HV2 intervention Error code | View |
| ER03 - Shutdown due to decrease in flue gas temperature Error code | View |
| ER04 - Shutdown due to water overtemperature Error code | View |
| ER05 - Shutdown due to flue gas overtemperature Error code | View |
| ER07 - No encoder signal from combustion fan Error code | View |
| ER08 - Combustion fan speed regulation failed Error code | View |
| ER09 - Low water pressure Error code | View |
| ER10 - High water pressure Error code | View |
| ER11 - Incorrect time/date values after long absence of mains power Error code | View |
| ER12 - Ignition failed Error code | View |
| ER15 - Power supply fault Error code | View |
| ER16 - RS485 communication error Error code | View |
| ER17 - Air flow regulation failed Error code | View |
| ER18 - Lack of fuel Error code | View |
| ER23 - Boiler probe, boiler return probe, buffer tank probe, or low buffer tank probe open Error code | View |
| ER25 - Cleaning motor fault Error code | View |
| ER26 - Cleaning motor 2 fault Error code | View |
| ER27 - Cleaning motor 3 fault Error code | View |
| ER39 - Flowmeter sensor fault Error code | View |
| ER41 - Minimum air flow in Check Up not reached Error code | View |
| ER42 - Maximum air flow exceeded (FL40) Error code | View |
| ER44 - Door error Error code | View |
| ER47 - No encoder signal from auger Error code | View |
| ER48 - Auger speed regulation failed Error code | View |
| ER56 - Modified hydraulic plant Error code | View |