High-performance 35 kW pellet boiler with automatic cleaning, high efficiency, and low emissions. Designed for large buildings, industrial installations, and utility projects. Read more
  • Powerful 35 kW output for industrial and large-scale heating systems
  • Automatic cleaning of burner and heat exchanger
  • High efficiency with low pellet consumption
  • Compatible with professional buffer tanks and hybrid setups
  • Quiet and low-maintenance operation
  • Optional BigTank with up to 225 kg storage capacity
  • Robust and durable design for intensive use

Designed for maximum heating capacity

The Kepo AC 35 pellet boiler is the flagship model in the AC series, built for situations with exceptionally high heating demand. With a thermal output of 35 kW, it is ideal for large commercial facilities, agricultural complexes, industrial plants, and extensive utility projects. Combining sustainable wood pellets with a robust, heavy-duty design, the AC 35 delivers consistent heat even under the toughest conditions.

Industrial-grade reliability

Equipped with premium components and a fully automatic cleaning system for both the burner and heat exchanger, the AC 35 maintains peak performance with minimal maintenance, even during continuous operation over long heating seasons.

Energy efficiency and advanced combustion

The smart control system automatically adjusts combustion parameters based on the actual heating requirement. This ensures high efficiency, reduced pellet consumption, and exceptionally clean combustion that meets the strictest emission standards.

Flexible integration

The AC 35 can be seamlessly paired with professional buffer tanks for pellet boilers and works in both low- and high-temperature systems. It can also be integrated into hybrid heating setups, offering additional flexibility for renovation or expansion projects. With the optional BigTank, pellet storage capacity increases to 225 kg for extended autonomous operation.

User-friendly and quiet operation

The intuitive 4.3” touchscreen makes operation straightforward, while the weekly program allows automatic switching between modes. Despite its high output, the AC 35 operates quietly enough for installation in an outbuilding or technical room without causing disturbances.

Support from Hewa

Hewa offers full support for both installers and end users – from technical documentation and on-site advice to fast delivery. Learn more about our pellet boiler solutions for large installations or contact us directly for expert advice or a no-obligation quote.


Generals
Item number 020104
EAN Code 8721082877145
Price excl. VAT € 4.647,70
Price incl. VAT € 4.499,00
Sizes ((LxWxH):) 105 x 77 x 160 cm
Specification list
Weight (kg) 416 kg
Dimension (W×D×H) mm 765x1040x1600 mm
Flue pipe diameter (Ø) 120 mm
Pellet tank capacity (kg) 120 kg
Power consumption at start on pellet (W) 400 W
Power consumption in operation (W) 115 W
Nominal voltage (VAC) 220 - 240 VAC
Nominal frequency (Hz) 50 Hz
Water pipe connection size G 1 1/4" M
Safety valve pipe connection G 1/2" F
Pump flow rate (L/h) 1300 L/h
Boiler water volume (L) 98 L
Boiler power (kW) min 8.70– max 35.70 kW
Pellet consumption (kg/h) min 2.10 – max 8.60 kg/h
Water temperature (°C) min 60 – max 80 °C
Min. boiler water pressure (bar) 0.6 bar
Max. boiler water pressure (bar) 2.5 bar
Preferred pellet class C1 - A1
Boiler class 5
Energy efficiency A+
Suitable surface area (m²) 170 - 330 m²
Fuel Wood pellets
Document Action
Brochure
Catalog PDF Download
Installation guide
Installation guide PDF Download
Technical data
Hydraulic diagram PDF Download
Necessary conditions PDF Download
Technical drawing PDF Download
Subject Action
How to clean a Kepo pellet boiler faq View
How to replace the igniter of a Kepo pellet boiler faq View
ER01 - Safety thermostat HV1 intervention Error code View
ER02 - Safety pressure switch HV2 intervention Error code View
ER03 - Shutdown due to decrease in flue gas temperature Error code View
ER04 - Shutdown due to water overtemperature Error code View
ER05 - Shutdown due to flue gas overtemperature Error code View
ER07 - No encoder signal from combustion fan Error code View
ER08 - Combustion fan speed regulation failed Error code View
ER09 - Low water pressure Error code View
ER10 - High water pressure Error code View
ER11 - Incorrect time/date values after long absence of mains power Error code View
ER12 - Ignition failed Error code View
ER15 - Power supply fault Error code View
ER16 - RS485 communication error Error code View
ER17 - Air flow regulation failed Error code View
ER18 - Lack of fuel Error code View
ER23 - Boiler probe, boiler return probe, buffer tank probe, or low buffer tank probe open Error code View
ER25 - Cleaning motor fault Error code View
ER26 - Cleaning motor 2 fault Error code View
ER27 - Cleaning motor 3 fault Error code View
ER39 - Flowmeter sensor fault Error code View
ER41 - Minimum air flow in Check Up not reached Error code View
ER42 - Maximum air flow exceeded (FL40) Error code View
ER44 - Door error Error code View
ER47 - No encoder signal from auger Error code View
ER48 - Auger speed regulation failed Error code View
ER56 - Modified hydraulic plant Error code View