| Document | Action |
|---|---|
| Technische gegevens (pagina 7) | |
| Technische gegevens (pagina 7) PDF | Download |
BURNiT SNS SWPN-2L 200 - Hot Water Cylinder with Enlarged Heat Exchanger (200L)
- Enlarged 2.8 m² heat exchanger for heat pump systems
- 200-litre nominal storage capacity
- Corrosion protection with titanium enamel and magnesium anode
- 50 mm high-performance rigid PU insulation
- Energy efficiency class B
- Prepared for an optional 3 kW electric heating element
BURNiT SUNSYSTEM SWPN-2L 200 Hot Water Cylinder for Heat Pumps
The BURNiT SUNSYSTEM SWPN-2L 200 is an indirect domestic hot water cylinder with a nominal capacity of 200 litres, specifically developed for hot water production using heat pumps. Combining an enlarged heat exchanger, an enamelled steel tank and high-performance thermal insulation, this cylinder is designed for modern installations where efficient heat transfer is essential.
The SWPN-2L series is intended for use with external heat sources operating at relatively low flow temperatures, such as air-to-water heat pumps. Its enlarged heat transfer surface supports efficient heating of the stored domestic hot water.
Enlarged 2.8 m² Heat Exchanger
The SWPN-2L 200 features a paired heat exchanger with a total surface area of 2.8 m² and an internal volume of 18 litres. The twin-coil arrangement forms a single hydraulic circuit with one flow and one return connection.
The enlarged heat transfer surface allows heat to be transferred efficiently, even at the relatively low flow temperatures used in heat pump systems. Under the specified manufacturer test conditions, the heat exchanger delivers 25.1 kW at a heat transfer fluid temperature of 55 °C and a flow rate of 3.06 m³/h. Actual performance depends on the connected heat source, temperature differences and hydraulic operating conditions.
Enamelled Steel Tank with Corrosion Protection
The storage tank is manufactured from S235JR steel and protected internally with a titanium enamel coating. A magnesium anode provides additional protection against corrosion and helps protect the tank during operation.
For periodic maintenance, the cylinder features an inspection opening with flange. The magnesium anode can be inspected and replaced when necessary in accordance with the manufacturer's maintenance instructions.
High-Performance PU Insulation for Energy-Efficient Storage
The cylinder is insulated with 50 mm rigid polyurethane foam to reduce heat loss during storage. The exterior is finished with a protective PVC jacket in RAL 9006. The SWPN-2L 200 is assigned energy efficiency class B by the manufacturer.
The vertical construction has an overall height of 1252 mm and a diameter of 610 mm including insulation, according to the SUNSYSTEM 2026 catalogue. This makes the cylinder suitable for floor-standing installation in an appropriate technical room.
Technical Features
- Nominal capacity: 200 litres
- Heat exchanger surface area: 2.8 m²
- Heat exchanger volume: 18 litres
- Heat exchanger output: 25.1 kW under manufacturer test conditions
- Maximum tank operating pressure: 8 bar
- Maximum heat exchanger operating pressure: 16 bar
- Maximum tank temperature: 95 °C
- Maximum heat exchanger temperature: 110 °C
- Insulation: 50 mm rigid PU foam
- Height: 1252 mm
- Diameter including insulation: 610 mm
- Empty weight: 108 kg
- Energy efficiency class: B
Connections and Optional Accessories
The SWPN-2L 200 is equipped with connections for cold water, hot water, domestic hot water recirculation and the heat exchanger flow and return. The cold water inlet, hot water outlet and heat exchanger connections have a nominal 1-inch female thread (Rp 1"). The recirculation connection features an Rp 3/4" female thread.
Additional connections are provided for temperature sensors, venting and draining. An optional 3 kW electric heating element can be installed using the designated connection. This element is not included as standard.
Installation and Application
The BURNiT SUNSYSTEM SWPN-2L 200 is designed for domestic hot water production using an external heat source. When combined with a heat pump, the available heating capacity, required hot water temperature, flow rate and heat exchanger performance must be considered together.
The cylinder is designed for vertical floor-standing installation. Allow sufficient clearance for pipe connections, inspection and maintenance. Installation and commissioning must comply with the manufacturer's instructions and applicable installation regulations.
Hewa supports installers in selecting suitable domestic hot water cylinders and matching installation components for heat pump systems.
| Generals | |
|---|---|
| Item number | 129200 |
| EAN Code | 8721225902772 |
| Price excl. VAT | € 950,37 |
| Price incl. VAT | € 1.149,95 |
| Sizes ((LxWxH):) | 61 x 61 x 125 cm |
| Specification list | |
| Volume | 200L |
| Diameter | 610 mm |
| Height | 1252 mm |
| Insulation layer thickness | 50 mm |
| Insulation layer | Hard PU-schuim |
| Working pressure buffer tank | 8 bar |
| Working pressure DHW tank | 16 bar |
| Empty weight | 108 kg |
| Cold water inlet | G 1" F / 207 mm |
| Hot water outlet | G 1" F / 1047 mm |
| Recirculation | G 3/4" F / 771 mm |
| Bottom flush inlet S1 | G 1" F / 1022 mm |
| Bottom flush outlet S1 | G 1" F / 207 mm |
| Air vent | G 1" F / 1252 mm |
| Drain pipe | G 1" F / 30 mm |
| Warmtewisselingsoppervlak S1 | 2.8 m² |
| Inhoud | 200L |
| Inner tank material | S235JR enamelled |
| Heat exchanger surface area | 2.8 m² |